Skip to content
Standard PVC

Is used in mechanically attached and fully adhered roofing systems in new construction, reroofing and recover (retrofit) applications. It may also be used as flexible membrane flashings for walls, curbs, etc, when installing PVC membrane roofing systems. The system must be installed over acceptable roof insulation or other suitable substrate. See the Mule-Hide PVC Specifications Manual for complete specifications and detail

Colors

System

PVC
  • Polyester-reinforced
  • Available in 40.5", 81", 5' and 10' widths (60 mil minimum is 5' and 10' widths only)
  • 50, 60, 80 mil thickness and 60 and 80 mil minimum
  • Fully adhered and mechanically attached systems
  • Available in white, gray and tan
  • Most often installed as fully adhered
  • Up to a 25 year system warranty available
  • Can be installed with Hydrobond wet lay-in or solvent based contact adhesive
  • Pre-printed with lap lines and fastener spacing
  • All PVC accessories can be used on standard or KEE HP membrane
  • Excellent chemical resistance, better solution for food service industry over TPO
  • More flexible and easier to work with than TPO
  • Will smoke when welding
  • Meets  UL Standards
  • Meets  C-UL Standards
  • Meets  FM Standards
  • Meets  CCMC Standards
  • Meets  Miami-Dade-County Standards
  • Meets  Florida-Building Standards
  • Meets  CRRC Standards
  • Meets  CA-Title-24 Standards
  • Meets  ICC-ES Standards

Documents

PDS Low-VOC PVC Step 1 Activator
PDS Low-VOC PVC Step 2 Primer
PDS PVC Overlayment Strip
PDS PVC Pressure-Sensitive Cover Strip
PDS PVC Step 2 Primer
PDS PVC Systems Membrane
PDS PVC Systems Membrane - Minimum
SDS - Statement for Article Products
SDS Low-VOC PVC Step 1 Activator
SDS Low-VOC PVC Step 2 Primer
SDS PVC Step 2 Primer

CCMC - Canadian Construction Materials Centre evaluation for PVC Systems
Florida Product Approval - HVHZ - PVC Systems
Florida Product Approval - PVC Systems
ICC-ESR Report - Adhered and Mech. Attached EPDM Systems, TPO Systems & PVC Systems
Miami-Dade NOA - PVC Systems over Cementitious Wood Fiber Decks
Miami-Dade NOA - PVC Systems over Concrete Decks
Miami-Dade NOA - PVC Systems over Poured Gypsum Decks
Miami-Dade NOA - PVC Systems over Recover Decks
Miami-Dade NOA - PVC Systems over Steel Decks
Miami-Dade NOA - PVC Systems over Wood Decks
TDI - Texas Department of Insurance - TPO Systems & PVC Systems MA over wood
UL - Impact resistance ratings for PVC Systems
UL - Overview of UL Listings for PVC Systems

Custom Single-Ply Accessories Form
Letter of Compliance Application- Photovoltaic Installation on Mule-Hide Warranted Roof
Mule-Hide Products Company Brochure
Procedure for Inclusion of Photovoltaic Anchor Flashings
PVC Cross Reference Chart
PVC Metal Retrofit
PVC Pocket Guide
PVC Pocket Guide (Spanish)
PVC Systems Contractor Brochure
Reduced Fastener Requirements for Uplift Ratings
Sell Sheet - Why Choose PVC
Single-Ply Roofing Accessories Guide
Talking Points - PVC Comparison
Talking Points - PVC Roofing Systems
Tech Bulletin - Mechanically Fastened Splice Requirements
Tech Bulletin - Pactiv GreenGuard Insulation

Design Summary - PVC Fleece Back Systems 10 or 15 year Fully Adhered
Design Summary - PVC Systems 10 or 15 year Fully Adhered
Design Summary - PVC Systems 10 or 15 year Mechanically Attached
E-Z Residential (Single-Family) Warranty Application - Material Only
Warranty - Notice of Completion
Warranty Program Information - Heat Weld Systems

Details

BASE ATTACHMENT PVC - ALL-PURPOSE BAR
PARAPET FLASHING FOR PVC
Rhinobond Base Attachment

FIELD FABRICATED INSIDE CORNER FOR PVC
FIELD FABRICATED OUTSIDE CORNER FOR PVC
INSIDE CORNER WITH COATED METAL WALL FLASHING FOR PVC
PRE-MOLDED INSIDE CORNER FLASHING FOR PVC
PRE-MOLDED OUTSIDE CORNER FOR PVC
PRE-MOLDED OUTSIDE CORNER ON COATED METAL WALL FLASHING FOR PVC

CURB FLASHING FOR PVC
PVC COATED GRAVEL STOP FOR FLEECE BACK
PVC COATED WALL FLASHING

MECHANICALLY FASTENED TARGET ROOF DRAIN FOR PVC
PREMANUFACTURED CONDUCTOR HEAD
ROOF DRAIN - SUMPS SLOPED MORE THAN 3 inch PER FOOT FOR PVC
ROOF DRAIN - SUMPS SLOPED MORE THAN 3" PER FOOT - 1 OF 2
ROOF DRAIN - SUMPS SLOPED MORE THAN 3" PER FOOT - 2 OF 2
ROOF DRAIN FOR DRAIN SUMPS SLOPED LESS THAN 3 inch PER FOOT FOR PVC
ROOF DRAIN FOR DRAIN SUMPS SLOPED MORE THAN 3 inch PER FOOT FOR PVC

EXPANSION JOINT - DECK TO DECK
EXPANSION JOINT - DECK TO DECK FOR PVC
EXPANSION JOINT AT JUNCTION OF DECK AND WALL
EXPANSION JOINT AT JUNCTION OF DECK AND WALL FOR PVC

CONCRETE PAVER WALKWAY
MH-100 PVC Walkway

2 inch OR THICKER INSULATION ATTACHMENT - 8 FASTENERS PER 4ft X 8ft BOARD
Extruded Polystyrene Insulation Attachment Fastening Patterns
FM - 10 Field Fasteners per 4'x8' Board
FM - 12 FIELD FASTENERS PER 4ft X 8ft BOARD PATTERN LAYOUT
FM - 16 FIELD FASTENERS PER 4ft X 8ft BOARD PATTERN LAYOUT
FM - 17 FIELD FASTENERS PER 4ft X 8ft BOARD PATTERN LAYOUT
FM - 6 Field Fasteners per 4'x8' Board
FM - 8 FIELD FASTENERS PER 4ft X 8ft BOARD PATTERN LAYOUT
FM - 8 Field Fasteners per 4'x8' Board
HELIX MAX FOAM ADHESIVE 12" RIBBON PATTERN
HELIX MAX FOAM ADHESIVE 4" RIBBON PATTERN
HELIX MAX FOAM ADHESIVE 6" RIBBON PATTERN
INSULATION ATTACHMENT - 12 FASTENERS PER 4ft X 8ft IN FIELD
INSULATION ATTACHMENT - 16 FASTENERS PER 4ft X 8ft IN FIELD
INSULATION ATTACHMENT - 17 FASTENERS PER 4ft X 8ft IN FIELD
INSULATION ATTACHMENT PATTERNS FOR MECHANICALLY ATTACHED SYSTEMS
Rhinobond Fastening Requirements

FIELD MEMBRANE LAYOUT FOR PVC
MEMBRANE SECUREMENT FOR PVC
PERIMETER ATTACHMENT FOR PVC
ROOF PERIMETER/CORNER CALCULATIONS ELEVATION DIFFERENCE 3ft OR LESS FOR PVC
ROOF PERIMETER/CORNER CALCULATIONS ELEVATION DIFFERENCE GREATER THAN 3ft FOR PVC

FIELD FABRICATED HOT PIPE FOR PVC
FIELD FABRICATED PIPE FLASHING FOR PVC
MEMBRANE COATED METAL PITCH PAN FOR PVC
MOLDED SEALANT POCKET FOR PVC
PREFABRICATED SQUARE TUBING WRAP FOR PVC
PVC PRE-MOLDED PIPE FLASHING
SLEEPER SUPPORT (HEAVY WEIGHT) FOR PVC - OPTION 2
SLEEPER SUPPORT (HEAVY WEIGHT) FOR PVC - OPTION 3
SLEEPER SUPPORT (LIGHT WEIGHT) FOR PVC - OPTION 1

ALL-PURPOSE BAR EDGE TERMINATION FOR PVC
COATED METAL BUTT JOINT FOR PVC
DRIP EDGE FOR ALL PVC SYSTEMS
DRIP EDGE FOR PVC
EDGE TERMINATION - ALL-PURPOSE BAR FOR PVC
GUTTER TERMINATION FOR FLEECE BACK PVC
GUTTER TERMINATION FOR PVC
MEMBRANE COATED GRAVEL STOP FOR PVC
PVC COATED GRAVEL STOP
WOOD NAILER ATTACHMENT FOR PVC

"T" JOINT COVER PATCH .060" (60 MIL) OR THICKER MEMBRANES
LAP CROSS SECTION FOR PVC - OPTION 1
LAP CROSS SECTION FOR PVC - OPTION 2
PLATE AND FASTENER PLACEMENT FOR PVC
SEAM INTERSECTION FOR FLEECE BACK PVC
SEAM INTERSECTION FOR PVC
T-JOINT DETAIL 50 MIL MEMBRANE FOR PVC
WHITE UNCURED EPDM "T" JOINT COVER .060" (60 MIL) OR THICKER MEMBRANE

CONCRETE PARAPET WALL WITH TERMINATION BAR FOR PVC
COPING STONE FOR PVC
CURB/WALL FLASHING WITH COUNTERFLASHING FOR PVC
CURB/WALL FLASHING WITH M-H ALL-PURPOSE BAR FOR PVC
METAL CAP TERMINATION FOR PVC
PREMANUFACTURED ARCHED COPING WITH SPLICE PLATE
PREMANUFACTURED METAL EDGE EXTENDER
PREMANUFACTURED REGLET COUNTERFLASHING
PREMANUFACTURED SURFACE MOUNTED COUNTERFLASHING
REGLET COUNTERFLASHING TERMINATION FOR PVC
SURFACE MOUNTED COUNTERFLASHING FOR PVC
TERMINATION BAR AT CORNER FOR PVC
TERMINATION BAR AT TILT-UP WALL JOINT FOR PVC
TERMINATION BAR FOR PVC
TERMINATION BAR WITH COUNTERFLASHING FOR PVC
TERMINATION ELEVATION CHANGE FOR PVC

COATED METAL TRANSITION TO SHINGLE ROOF FOR PVC
MEMBRANE FLASHING TRANSITION TO SHINGLE ROOF FOR PVC
TIE-IN TO EXISTING SINGLE PLY FOR PVC

RIDGE MEMBRANE ATTACHMENT FOR PVC

Specifications

Specification - PVC / PVC KEE Fully Adhered
Specification Supplement - AeroWeb Adhesive
Summary Specification - PVC Fleece Back Systems Fully Adhered
Summary Specification - PVC Systems Fully Adhered

Guide - Equipment needed to install Heat-Welded Membranes
Guide - Insulation Guidelines
Guide - PVC Systems HydroBOND Installation Guide
Guide - PVC Systems Installation Guidelines
Guide - Roof Mounted Photovoltaic Installations
Single-Ply Insulation Attachment Guidelines
Tech Note - Design Wind Speed vs Warranted Wind Speed
Tech Note - Sheet Flutter on Mechanically Attached Systems

Specification - PVC Systems Mechanically Attached
Summary Specification - Induction Welding Attachment Method
Summary Specification - PVC Fleece Back Systems Mechanically Attached
Summary Specification - PVC Systems Mechanically Attached
Summary Specification - PVC Systems metal retrofit attached into purlins

Options

Item ID Description Packaging Qty per Ctn Weight per Ctn Cover Rate
07MHP5051G MH PVC 50 MIL 5 X 100 REIN GRY Shrink Wrap 1 182 500 Sq.Ft/RL
07MHP5051T MH PVC 50 MIL 5 X 100 REIN TAN Shrink Wrap 1 182 500 Sq.Ft/RL
07MHP5051W MH PVC 50 MIL 5 X 100 REIN WHT Shrink Wrap 1 182 500 Sq.Ft/RL
07MHP5101G MH PVC 50 MIL 10 X 100 REIN GRY Shrink Wrap 1 360 1000 Sq.Ft/RL
07MHP5101T MH PVC 50 MIL 10 X 100 REIN TAN Shrink Wrap 1 360 1000 Sq.Ft/RL
07MHP5101W MH PVC 50 MIL 10 X 100 REIN WHT Shrink Wrap 1 360 1000 Sq.Ft/RL
07MHP5401G MH PVC 50 MIL 40.5" X 100' REIN GRY Shrink Wrap 1 122 337.5 Sq.Ft/RL
07MHP5401T MH PVC 50 MIL 40.5" X 100' REIN TAN Shrink Wrap 1 122 337.5 Sq.Ft/RL
07MHP5401W MH PVC 50 MIL 40.5 X 100 REIN WHT Shrink Wrap 1 122 337.5 Sq.Ft/RL
07MHP5811G MH PVC 50 MIL 81" X 100' REIN GRY Shrink Wrap 1 243 675 Sq.Ft/RL
07MHP5811T MH PVC 50 MIL 81" X 100' REIN TAN Shrink Wrap 1 243 675 Sq.Ft/RL
07MHP5811W MH PVC 50 MIL 81" X 100' REIN WHT Shrink Wrap 1 243 675 Sq.Ft/RL
07MHP6051G MH PVC 60 MIL 5 X 100 REIN GRY Shrink Wrap 1 228 500 Sq.Ft/RL
07MHP6051T MH PVC 60 MIL 5 X 100 REIN TAN Shrink Wrap 1 228 500 Sq.Ft/RL
07MHP6051W MH PVC 60 MIL 5 X 100 REIN WHT Shrink Wrap 1 228 500 Sq.Ft/RL
07MHP6101G MH PVC 60 MIL 10 X 100 REIN GRY Shrink Wrap 1 448 1000 Sq.Ft/RL
07MHP6101T MH PVC 60 MIL 10 X 100 REIN TAN Shrink Wrap 1 448 1000 Sq.Ft/RL
07MHP6101W MH PVC 60 MIL 10 X 100 REIN WHT Shrink Wrap 1 448 1000 Sq.Ft/RL
07MHP611MW MH PVC 60 MIL MINIMUM 10X100 REIN WHT Shrink Wrap 1 434 1000 Sq.Ft/RL
07MHP6401G MH PVC 60 MIL 40.5 X 100 REIN GRY Shrink Wrap 1 149 337.5 Sq.Ft/RL
07MHP6401T MH PVC 60 MIL 40.5 X 100 REIN TAN Shrink Wrap 1 149 337.5 Sq.Ft/RL
07MHP6401W MH PVC 60 MIL 40.5 X 100 REIN WHT Shrink Wrap 1 149 337.5 Sq.Ft/RL
07MHP651MW MH PVC 60 MIL MINIMUM 5X100 REIN WHT Shrink Wrap 1 217 500 Sq.Ft/RL
07MHP6811G MH PVC 60 MIL 81" X 100' REIN GRY Shrink Wrap 1 266 675 Sq.Ft/RL
07MHP6811T MH PVC 60 MIL 81" X 100' REIN TAN Shrink Wrap 1 266 675 Sq.Ft/RL
07MHP6811W MH PVC 60 MIL 81" X 100' REIN WHT Shrink Wrap 1 266 675 Sq.Ft/RL
07MHP8057G MH PVC 80 MIL 5' X 75' REIN GRY Shrink Wrap 1 233 375 Sq.Ft/RL
07MHP8057T MH PVC 80 MIL 5' X 75' REIN TAN Shrink Wrap 1 233 375 Sq.Ft/RL
07MHP8057W MH PVC 80 MIL 5' X 75' REIN WHT Shrink Wrap 1 233 375 Sq.Ft/RL
07MHP8107G MH PVC 80 MIL 10' X 75' REIN GRY Shrink Wrap 1 464 750 Sq.Ft/RL
07MHP8107T MH PVC 80 MIL 10' X 75' REIN TAN Shrink Wrap 1 464 750 Sq.Ft/RL
07MHP8107W MH PVC 80 MIL 10' X 75' REIN WHT Shrink Wrap 1 464 750 Sq.Ft/RL
07MHP8407G MH PVC 80 MIL 40.5 X 75 REIN GRY Shrink Wrap 1 143 253.125 Sq.Ft/RL
07MHP8407T MH PVC 80 MIL 40.5 X 75 REIN TAN Shrink Wrap 1 143 253.125 Sq.Ft/RL
07MHP8407W MH PVC 80 MIL 40.5 X 75 REIN WHT Shrink Wrap 1 143 253.125 Sq.Ft/RL
07MHP8817G MH PVC 80 MIL 81" X 75' REIN GRY Shrink Wrap 1 277 506.25 Sq.Ft/RL
07MHP8817T MH PVC 80 MIL 81" X 75' REIN TAN Shrink Wrap 1 277 506.25 Sq.Ft/RL
07MHP8817W MH PVC 80 MIL 81" X 75' REIN WHT Shrink Wrap 1 277 506.25 Sq.Ft/RL

FAQs

To reduce blocking, packs should only be stacked 4-packs up to five high. We have found that when stacked higher, the bottom rolls could crush a bit which could create blocking and a wavy sheet when installed. It is possible that the stacking issue can be heightened over the summer months due to the heat.