Is used in fully adhered roofing systems in new construction, reroofing and recover (retrofit) applications. It may also be used as flexible membrane flashings for walls, curbs, etc, when installing TPO-c membrane roofing systems. The system must be installed over acceptable roof insulation or other suitable substrate. See the Mule-Hide TPO Specifications Manual for complete specifications and details.

System

TPO
  • Polyester-reinforced
  • Available in 10' widths only
  • 60 mil thickness available in White, Gray or Tan
  • Fully adhered systems only
  • 80 mil thickness available in white only
  • Up to a 20 year system warranty available
  • Pre-printed with lap lines
  • Cannot be installed when sheet & ambient temperature is under 25°F (-4°C), confirm sheet temp with temperature gun.
  • Split release liner
  • Segmented weighted roller required to ensure proper adhesion.
  • Cannot be used over wood fiber board, EPS or XPS
  • End laps are butted and stripped in
  • Standard TPO membrane is used as flashing
  • Meets  UL Standards
  • Meets  C-UL Standards
  • Meets  FM Standards
  • Meets  CCMC Standards
  • Meets  CRRC Standards
  • Meets  CA-Title-24 Standards
  • Meets  ICC-ES Standards

Documents

PDS TPO Systems-c Self-Adhering TPO
SDS - Statement for Article Products

CCMC - Canadian Construction Materials Centre evaluation for TPO Systems
Florida Product Approval - TPO Systems
ICC-ESR Report - Adhered and Mech. Attached EPDM Systems, TPO Systems & PVC Systems
ICC-ESR Report - Ballasted EPDM Systems and TPO Systems
Miami-Dade NOA - TPO Systems over Cement Wood Fiber
Miami-Dade NOA - TPO Systems over Concrete Deck
Miami-Dade NOA - TPO Systems over Gypsum
Miami-Dade NOA - TPO Systems over Light Weight Concrete
Miami-Dade NOA - TPO Systems over Steel Deck
Miami-Dade NOA - TPO Systems Recover applications
TDI - Texas Department of Insurance - TPO Systems & PVC Systems MA over wood
TDI - Texas Department of Insurance - TPO Systems MA over Steel Deck
UL - Impact resistance ratings for TPO Systems
UL - Overview of UL Listings for TPO Systems
UL - Summary of UL Listings for TPO Systems

Eight Reasons to Choose a TPO System
Hail Coverage - Procedures and Requirements
Letter of Compliance Application- Photovoltaic Installation on Mule-Hide Warranted Roof
Procedure for Inclusion of Photovoltaic Anchor Flashings
Single-Ply Roofing Accessories Guide
TPO Cross Reference Chart
TPO Metal Retrofit
TPO Pocket Guide
TPO Pocket Guide (Spanish)
TPO Systems Brochure

Design Enhancements - Single-Ply Membranes
Design Summary - TPO Fleece Back Systems 10 or 15 year Fully Adhered
Design Summary - TPO Systems 10 or 15 year Ballasted
Design Summary - TPO Systems 10 or 15 year Fully Adhered
Design Summary - TPO Systems 10 or 15 year Mechanically Attached
E-Z Residential (Single-Family) Warranty Application - Material Only
Warranty - Notice of Completion
Warranty Program Information - Heat Weld Systems

Details

BASE ATTACHMENT TPO- ALL -PURPOSE BAR
BASE ATTACHMENT USING 6 inch STANDARD TPO-C MEMBRANE
BASE ATTACHMENT WITH PLATES AND FASTENERS
DOOR THRESHOLD FLASHING

2-PIECE OUTSIDE CORNER UNCURED EPDM
FIELD FABRICATED INSIDE CORNER FOR TPO
FIELD FABRICATED OUTSIDE CORNER FOR TPO
INSIDE CORNER - UNCURED EPDM
INSIDE CORNER FOR TPO
TPO UNIVERSAL CORNER - OUTSIDE CORNER

CURB FLASHING FOR TPO
CURB FLASHING WITH M-H ALL-PURPOSE BAR
CURB/WALL FLASHING WITH M-H ALL-PURPOSE BAR - FLEECE BACK & SELF-ADHERING TPO
CURB/WALL FLASHING WITH M-H ALL-PURPOSE BAR FOR TPO
INSULATED PARAPET WALL WITH METAL COPING CAP FOR TPO
PARAPET WALL DETAIL - EXISTING COPING CAP FOR TPO
PARAPET WALL DETAIL - METAL COPING CAP FOR TPO
PARAPET/CURB FLASHING FOR EPDM

DUTCH GUTTER FOR EPDM AND TPO
GRAVEL STOP SCUPPER - TPO COATED METAL
INTERMITTENT WALL SCUPPER FOR EPDM
NEW METAL THROUGH-WALL SCUPPER WITH WHITE UNCURED EPDM FOR TPO
PREMANUFACTURED CONDUCTOR HEAD
RETROFIT DRAIN INSERT - COMPRESSION TYPE INSERT FOR TPO
ROOF DRAIN FOR EPDM AND TPO
THROUGH-WALL SCUPPER - TPO COATED METAL
THROUGH-WALL SCUPPER - TPO COATED METAL

EXPANSION JOINT - CURB FOR TPO
EXPANSION JOINT CURB WITH CLOSED CELL ROD
EXPANSION JOINT DETAIL
EXPANSION JOINT DETAILS
WALL EXPANSION JOINT
WALL EXPANSION JOINT

4" TRAY PROFILE
TRANSITION TO WALKWAY
WALKWAY PAVER FOR EPDM AND TPO

2 inch OR THICKER INSULATION ATTACHMENT - 8 FASTENERS PER 4ft X 8ft BOARD
FM - 12 FIELD FASTENERS PER 4ft X 8ft BOARD PATTERN LAYOUT
FM - 16 FIELD FASTENERS PER 4ft X 8ft BOARD PATTERN LAYOUT
FM - 17 FIELD FASTENERS PER 4ft X 8ft BOARD PATTERN LAYOUT
FM - 8 FIELD FASTENERS PER 4ft X 8ft BOARD PATTERN LAYOUT
HELIX MAX FOAM ADHESIVE 12" RIBBON PATTERN
HELIX MAX FOAM ADHESIVE 4" RIBBON PATTERN
HELIX MAX FOAM ADHESIVE 6" RIBBON PATTERN
INSULATION ATTACHMENT - 12 FASTENERS PER 4ft X 8ft IN FIELD
INSULATION ATTACHMENT - 16 FASTENERS PER 4ft X 8ft IN FIELD
INSULATION ATTACHMENT - 17 FASTENERS PER 4ft X 8ft IN FIELD

ROOF CORNER AND PERIMETER DETAIL
ROOF PERIMETER/CORNER CALCULATION ELEVATION DIFFERENCE 3ft OR LESS FOR TPO
ROOF PERIMETER/CORNER CALCULATION ELEVATION DIFFERENCE GREATER THAN 3ft FOR TPO

FIELD FABRICATED PIPE FLASHING WITH BANDING CLAMP FOR TPO
FIELD FABRICATED PIPE FLASHING WITH SEAM TAPE FOR TPO
FIELD FABRICATED PIPE FLASHING WITH WHITE UNCURED EPDM
FIXED EQUIPMENT SUPPORT FOR TPO
HOT PIPE FLASHING WITH COLD SLEEVE FOR TPO
HOT PIPE FLASHING WITH COLD SLEEVE WITH UNCURED EPDM
I-BEAM SUPPORT FLASHING FOR TPO
LIGHTNING CABLE STRAP FOR TPO
LIGHTNING ROD BASE FOR TPO
LIGHTNING ROD DETAIL
LIGHTNING ROD WALL SUPPORT FOR TPO
PITCH PAN MEMBRANE COATED METAL FOR TPO
PREFABRICATED SQUARE TUBING WRAP FOR TPO
PRE-MOLDED PIPE BOOT - WHITE EPDM
PRE-MOLDED PIPE BOOT FOR TPO
SLEEPER DETAIL FOR TPO
TPO MOLDED SEALANT POCKET
TPO SPLIT PIPE BOOT
WHITE EPDM PREFABRICATED SEALANT POCKET
WOOD SLEEPER FOR TPO

ALL-PURPOSE BAR - EDGE TERMINATION FOR TPO
ANCHOR-TITE FASCIA SYSTEM BY METAL-ERA, INC
DRIP EDGE - TPO PS COVER STRIP
DRIP EDGE - WHITE EPDM CURED COVER TAPE FOR TPO
EDGE TERMINATION - ALL-PURPOSE BAR FOR TPO
FASCIA / DRIP EDGE SYSTEM FOR TPO
GRAVEL STOP - TPO COATED METAL - OPTION 1
GRAVEL STOP - TPO COATED METAL - OPTION 2
GRAVEL STOP JOINT DETAIL - TPO COATED METAL
GUTTER / TERMINATION BAR - RECOVER FOR TPO
GUTTER / TERMINATION BAR - RECOVER FOR TPO
GUTTER DRIP EDGE - TPO COATED METAL
PREMANUFACTURED 2-PIECE COMPRESSION LARGE EDGE DETAIL FOR TPO
PREMANUFACTURED ARCHED DRIP EDGE WITH SPLICE CLIP FOR TPO
PREMANUFACTURED MEMBRANE COATED METAL PITCH PAN FOR TPO
SNAP-ON FASCIA FOR TPO
TAPERED EDGE / GRAVEL STOP FOR TPO

FIELD SEAM FOR TPO
FLEECE BACK END LAPS
MEMBRANE / SEAM REPAIR WHITE MATE-LINE TAPE
SEAM PATCH AT FIELD/WALL TRANSITION FOR TPO
T-JOINT COVER - 60 MIL OR THICKER MEMBRANES FOR TPO
T-JOINT DETAIL - 45 MIL THICK MEMBRANES FOR TPO
UNCURED EPDM SEAM PATCH AT FIELD / WALL TRANSITION
WHITE UNCURED EPDM "T" JOINT COVER .060" (60 MIL) OR THICKER MEMBRANE

BASE FLASHING AT SIDING FOR TPO
CURB/WALL FLASHING WITH COUNTERFLASHING FOR TPO
PREMANUFACTURED ARCHED COPING WITH SPLICE PLATE
PREMANUFACTURED METAL EDGE EXTENDER
PREMANUFACTURED REGLET COUNTERFLASHING
PREMANUFACTURED SURFACE MOUNTED COUNTERFLASHING
WALL FLASHING WITH COUNTERFLASHING FOR TPO

SEGREGATION DETAIL/GREEN ROOF AND EXISTING ROOF
SEGREGATION DETAIL/GREEN ROOF AND EXPOSED SINGLE PLY
TIE-IN - EXISTING BUR OR MOD BIT
TIE-IN - SHINGLE ROOF FOR TPO
TIE-IN TO EXISTING BUR / MOD BIT ROOF - RECOVER SITUATION FOR TPO
TIE-IN TO EXISTING EPDM OR HYPALON - TEAR-OFF SITUATION FOR TPO
TIE-IN TO SOLID DECK WITH CURB - CURB PARALLEL TO SLOPE WITH TEAR-OFF FOR TPO

RIDGE FLASHING FOR TPO
VALLEY FLASHING FOR TPO - OPTION 2

Specifications

Specification - TPO Systems Self Adhering
Summary Specification - TPO Systems Self Adhering

Guide - Equipment needed to install Heat-Welded Membranes
Guide - Insulation Guidelines
Guide - Roof Mounted Photovoltaic Installations
Guide - TPO Systems Installation Guidelines
Single-Ply Insulation Attachment Guidelines
Tech Note - Design Wind Speed vs Warranted Wind Speed
Tech Note - Sheet Flutter on Mechanically Attached Systems

Specification - TPO Systems Mechanically Attached
Summary Specification - TPO Systems Mechanically Attached
Summary Specification - Induction Welding Attachment Method
Summary Specification - TPO Systems Induction Welding Linear Attachment
Summary Specification - TPO Systems metal retrofit using RUSS
Summary Specification - TPO Systems metal retrofit-purlin attached

Options

Item ID Description Packaging Qty per Ctn Weight per Ctn Cover Rate
07MHST611W MH .060 SA-TPO 10' X 100' WHITE Shrink Wrap 1 330 1000 Sq.Ft/RL
07MHST615W MH .060 SA-TPO 10' X 50' WHITE Shrink Wrap 1 330 500 Sq.Ft/RL
07MHST611G MH .060 SA-TPO 10' X 100' GRAY Shrink Wrap 1 330 1000 Sq.Ft/RL
07MHST611T MH .060 SA-TPO 10' X 100' TAN Shrink Wrap 1 330 1000 Sq.Ft/RL
07MHST811W MH .080 SA-TPO 10' X 100' WHITE 0 1000 Sq. Ft/RL

FAQs

To reduce blocking, packs should only be stacked 4-packs up to five high. We have found that when stacked higher, the bottom rolls could crush a bit which could create blocking and a wavy sheet when installed. It is possible that the stacking issue can be heightened over the summer months due to the heat.